Fangpusun Grid 300 and Fangpusun Grid 500 The inverter comprises the Fangpusun Grid 300 and Fangpusun Grid 500 inverters, with rated outputs of 300 W and 500 W, respectively. The Grid 300 and the Grid 500 are built in a modular manner and are simple to install. With distribution over three...
Fangpusun Grid 300 and Fangpusun Grid 500
The inverter comprises the Fangpusun Grid 300 and Fangpusun Grid 500 inverters, with rated outputs of 300 W and 500 W, respectively.
The Grid 300 and the Grid 500 are built in a modular manner and are simple to install. With distribution over three phases, the system can at any time be expanded as desired, and thus flexibly adapts to your solar power system. fangpsun Grid 300 and fangpusun Grid 500 have an independent MPP tracker and achieve a very high efficiency of up to 95.8 %.
Product features
•Flexible and expandable
•High efficiency
•MiniString concept
•Low weight
•Simple installation
•Wall-mounting with top-hat rail
Electronic protection functions
•Integrated temperature monitoring with output derating
Displays
•Multi-coloured LED shows operating states
Options
•United Kingdom variants as per G83 available
Guarantee service
Steca MiniString inverters come with a 5-year guarantee. The guarantee period can be optionally extended up to 10 years.
Grid 300 | Grid 500 | ||||
DC input side(PV-generator | |||||
Maximum start voltage | 135V | 230V | |||
Maximum input voltage | 135V | 230V | |||
Minimum input voltage | 45V | ||||
Minimum input voltage for rated output | 64V | 106V | |||
MPP vntage | 45V -100v | 75v-170v | |||
Maximum inout current | 5A | ||||
Maximum input power at maximum active output power | 320W | 530W | |||
Maximum recommended Py power | 375Wp | 625Wp | |||
AC output side (Grid connaction) | |||||
Grid volage | 185. 276 V(copending on region settings) | ||||
Rated id voltage | 230V | ||||
Maximum output current | 1.5A | 2.17A | |||
Maximum active power (cos ph- 1) | 300W | 500W | |||
Rated power | 30W | 500W | |||
Rated fequency | 50 HZ | ||||
Fequency | 47 Hz.a. 52 Hz (depending on regional settings) | ||||
Night-time power loss | 0W | ||||
Feeding phases | |||||
Distortion factor (cos phi- 1) | <6%(max.power | <5%(max.power | |||
Power factor cos phi | 1 | ||||
Characterisation of the ap rating performance | |||||
Maximum efficiency | 94.8% | 95.8% | |||
European efficiency | 93.4% | 94.5% | |||
MPP efticiency | 99% | ||||
Power derating at full power | from 40℃ | ||||
standby power | 0W | ||||
Safety | |||||
Isolation principle | no galvanic isolation. transformerless | ||||
Grid manitoring version Grid 300 UK resp. 500UK | Voltage(230v+15%/-10%) frequency (50 Hz +0.5 Hz/-3 Hz) | voltage(230V+10%/-10%) frequency (50 Hz+0.5 Hz/-3 Hz) | |||
Grid monitoring version Grid 300 ES resp. 500ES | Voltage(230v+10%/-15%) Frequency (50 Hz+/-1Hz) | voltage(230V+10%/-15%) frequency (50 Hz+0.5 Hz/-1 Hz) | |||
Grid manitoring version Grid 300 IT resp 500 IT | voltage(230V +/-20 %) frequency (50Hz +/-0.3 Hz) | voltage(230V +/-20 %) frequency (50Hz +/-0.3 Hz) | |||
Operating conditions | |||||
Area of application | indoor rooms. with or without air condaionino | ||||
Ambient temperature | -20°c...+45°C | ||||
Relative humidity | 0%...95% | ||||
Noise emission | <32 dBA | ||||
Fitting and construction | |||||
Degree of protection | P20 | ||||
Overvoltage category | Ⅱ | ||||
DC output side connection | Multi-Contact Mc 3. MC 4 | ||||
AC output side connection | Stecker Weland Electric GST 18i3V | ||||
Dimensions (XxYxZ) | 176x243x71mm | ||||
Weight | 1.4kg | ||||
Communication interface | no | ||||
Integrated DC circuit breaker | no | ||||
Cooling principle | natural convection |