Grid 500W

Fangpusun Grid 300 and Fangpusun Grid 500 The inverter comprises the Fangpusun Grid 300 and Fangpusun Grid 500 inverters, with rated outputs of 300 W and 500 W, respectively. The Grid 300 and the Grid 500 are built in a modular manner and are simple to install. With distribution over three...

Product Details

Fangpusun Grid 300 and Fangpusun Grid 500

The inverter comprises the Fangpusun Grid 300 and Fangpusun Grid 500 inverters, with rated outputs of 300 W and 500 W, respectively.

The  Grid 300 and the Grid 500 are built in a modular manner and are simple to install. With distribution over three phases, the system can at any time be expanded as desired, and thus flexibly adapts to your solar power system. fangpsun Grid 300 and fangpusun Grid 500 have an independent MPP tracker and achieve a very high efficiency of up to 95.8 %.

Product features

•Flexible and expandable

•High efficiency

•MiniString concept

•Low weight

•Simple installation

•Wall-mounting with top-hat rail

Electronic protection functions

•Integrated temperature monitoring with output derating

Displays

•Multi-coloured LED shows operating states

Options

•United Kingdom variants as per G83 available

Guarantee service

Steca MiniString inverters come with a 5-year guarantee. The guarantee period can be optionally extended up to 10 years.



Grid 300

Grid 500

DC input side(PV-generator

Maximum start voltage

135V

230V

Maximum input voltage

135V

230V

Minimum input voltage

45V

Minimum input voltage for rated output

64V

106V

MPP vntage

45V -100v

75v-170v

Maximum inout current

5A

Maximum input power at maximum active output power

320W

530W

Maximum recommended Py power

375Wp

625Wp

AC output side (Grid connaction)

Grid volage

185. 276 V(copending on region settings)

Rated id voltage

230V

Maximum output current

1.5A

2.17A

Maximum active power (cos ph- 1)

300W

500W

Rated power

30W

500W

Rated fequency

50 HZ

Fequency

47 Hz.a. 52 Hz (depending on regional settings)

Night-time power loss

0W

Feeding phases


Distortion factor (cos phi- 1)

<6%(max.power

<5%(max.power

Power factor cos phi

1

Characterisation of the ap rating performance

Maximum efficiency

94.8%

95.8%

European efficiency

93.4%

94.5%

MPP efticiency

99%

Power derating at full power

from 40℃

standby power

0W

Safety

Isolation principle

no galvanic isolation. transformerless

Grid manitoring version Grid 300 UK resp. 500UK

Voltage(230v+15%/-10%)

frequency (50 Hz +0.5 Hz/-3 Hz)

voltage(230V+10%/-10%)

frequency (50 Hz+0.5 Hz/-3 Hz)

Grid monitoring version Grid 300 ES resp. 500ES

Voltage(230v+10%/-15%)

Frequency (50 Hz+/-1Hz)

voltage(230V+10%/-15%)

frequency (50 Hz+0.5 Hz/-1 Hz)

Grid manitoring version Grid 300 IT resp 500 IT

voltage(230V +/-20 %)

frequency (50Hz +/-0.3 Hz)

voltage(230V +/-20 %)

frequency (50Hz +/-0.3 Hz)

Operating conditions

Area of application

indoor rooms. with or without air condaionino

Ambient temperature

-20°c...+45°C

Relative humidity

0%...95%

Noise emission

<32 dBA

Fitting and construction

Degree of protection

P20

Overvoltage category

DC output side connection

Multi-Contact Mc 3. MC 4

AC output side connection

Stecker Weland Electric GST 18i3V

Dimensions (XxYxZ)

176x243x71mm

Weight

1.4kg

Communication interface

no

Integrated DC circuit breaker

no

Cooling principle

natural convection


Inquiry